Advanced Electrophysiology Systems

Discover cutting-edge intan electrophysiology solutions from White Mountain Systems

neuroscience research equipment

Intan RHD Recording System

The Intan RHD recording system is a modular, low-cost electrophysiology data acquisition system built around the Intan RHD family of microchips. The RHD recording system with USB interface and open-source software allows users to observe and record up to 1024 signals from multiple RHD headstages.

You need three basic components for a RHD recording system

RHD recording headstage

These are small circuit boards containing an Intan RHD amplifier chip that amplify, filter, and digitize signals from 16, 32, 64, or 128 electrodes. Unlike traditional headstages that provide limited analog amplification, Intan headstages perform all amplification on the headstage and produce a digital data stream conveying the signals from all electrodes.

RHD recording controller

This acts as a digital hub that links one or more headstages to a computer via a standard USB port. The RHD recording controller supports up to 1024 amplifier channels in a rack-mountable case with robust digital and analog I/O ports. Additional I/O ports may be added by using the optional I/O expander.

SPI interface cable

These cables link the headstages to the recording controller or USB interface board, sending power to the headstage and data back to the controller. They come in 1-ft (0.3 meter), 3-ft (0.9 meter), and 6-ft (1.8 meter) lengths, and in two thicknesses: standard and ultra thin. Multiple cables can be daisy-chained to create longer cables.

Intan provides free software to operate this system. The software allows users to select amplifier bandwidths and sampling rates, measure electrode impedances, view live signals from electrodes, and save data to disk. Recording sessions may be controlled manually or triggered automatically by external digital signals. We also provide free software to load saved data files into MATLAB, Python, or Julia, or to convert data files to NEX format.

We provide compiled, ready-to-run software for Windows PCs or Macs. You can download it and try it out before you buy Intan hardware; it will run in demo mode. We provide open-source C++/Qt source code that can be compiled for Linux.

Intan does not manufacture or sell electrodes, but many third-party companies sell electrodes that are compatible with our headstages. A list of compatible electrodes is provided with each RHD headstage.

Many of our customers use our system with commutators (i.e., slip rings or swivels). We do not sell commutators, but we do provide an application note describing how to adapt our SPI interface cables to any basic commutator. Also, Intan-ready motorized commutators with optical fiber ports are available from Alpha Omega (AlphaComm-I) and Doric (commutator with Intan adapter). Since our interface cables use purely digital signals, operation with commutators is typically robust and free of movement-induced noise.

Intan Technologies does not manufacture or sell any devices with wireless telemetry, but several third-party companies have developed wireless electrophysiology products and data loggers using Intan RHD amplifier chips.

Part
Recording Controllers
connect to computer via USB cable
Price
C3004
RHD 512-channel recording controller
includes USB cable and power cable
9,950.00
C3008
RHD 1024-channel recording controller
includes USB cable and power cable
14,250.00
E6500
I/O expander
for use with controller; includes interface cable
6,350.00
Part
RHD Headstages
headstages include Intan chip
Price
C3334
RHD 16-channel headstage
18-pin Omnetics electrode connector
805.00
C3335
RHD 16-channel headstage
18-pin Omnetics electrode connector
865.00
C3314
RHD 32-channel headstage
36-pin Omnetics electrode connector
940.00
C3324
RHD 32-channel headstage with accelerometer
36-pin Omnetics electrode connector
1,045.00
C3315
RHD 64-channel headstage
2x 36-pin Omnetics electrode connectors
1,875.00
C3325
RHD 64-channel headstage with accelerometer
2x 36-pin Omnetics electrode connector
2,045.00
C3316
RHD 128-channel headstage
2x 64-pin Molex electrode connectors
2,995.00
C3180
RHD electroplating board
DISCONTINUED Feb. 2022 due to supply chain issues
n/a
Part
Cables
connect RHD headstages to controller
Price
C3203
RHD 3-ft (0.9 m) standard SPI interface cable
215.00
C3206
RHD 6-ft (1.8 m) standard SPI interface cable
295.00
C3211
RHD 1-ft (0.3 m) ultra thin SPI interface cable
380.00
C3213
RHD 3-ft (0.9 m) ultra thin SPI interface cable
415.00
C3216
RHD 6-ft (1.8 m) ultra thin SPI interface cable
595.00
C3442
RHD dual headstage adapter
compatible with 16ch – 64ch RHD headstages
345.00
C3430
SPI cable adapter board
for interfacing with commutators or custom hardware
111.00
Part
Adapters
connect headstages to custom electrodes
Price
C3410
36-pin electrode adapter board
for headstages with 36-pin connector
255.00
C3418
18-pin electrode adapter board
for headstages with 18-pin connector
189.00
C3420
36-pin wire adapter
for headstages with 36-pin connector
230.00
B7600
18-pin wire adapter
for headstages with 18-pin connector
145.00

RHS (Recording and Stimulating) Systems

The RHS stimulation/recording system with USB interface and open-source software allows users to stimulate and record up to 128 signals from multiple RHS headstages. The minimum required components for a functional RHS system are: a stim/recording controller, a Stim SPI interface cable, and an RHS headstage.

You need three basic components to assemble a functional electrophysiology stim/recording system

RHS stim/recording headstage

These are small circuit boards containing an Intan RHS stim/amplifier chip that amplify, filter, and digitize signals from 16 or 32 electrodes and provide constant-current stimulation pulses. Unlike traditional headstages that provide limited analog amplification, Intan headstages perform all amplification on the headstage and produce a digital data stream conveying the signals from all electrodes.

RHS stim/recording controller

This acts as a digital hub that links one or more headstages to a computer via a standard USB port. The controller can stream up to 128 amplifier channels to a host computer at user-selectable sampling rates up to 30 kS/s per channel.

Stim SPI interface cable

These cables link the headstages to the stim/recording controller, sending power to the headstage and data back to the controller. They come in 3-ft (0.9 meter) and 6-ft (1.8 meter) lengths. Multiple cables can be daisy-chained to create longer cables.

Intan provides free software to operate this system. The software allows users to select amplifier bandwidths and sampling rates, measure electrode impedances, view live signals from electrodes, and save data to disk. Stimulation parameters may be configured in the GUI; stimulation pulses are triggered by digital inputs or keypresses. Recording sessions may be controlled manually or triggered automatically by external digital signals. We also provide free software to load saved data files into MATLAB, Python, or Julia, or to convert data files to NEX format.

We provide compiled, ready-to-run software for Windows PCs or Macs. You can download it and try it out before you buy Intan hardware; it will run in demo mode. We provide open-source C++/Qt source code that can be compiled for Linux.

Intan does not manufacture or sell electrodes, but many third-party companies sell electrodes that are compatible with our headstages. A list of compatible electrodes is provided with each RHS headstage.

Many of our customers use our system with commutators (i.e., slip rings or swivels). We do not sell commutators, but we do provide an application note describing how to adapt our Stim SPI interface cables to any basic commutator. Since our interface cables use purely digital signals, operation with commutators is typically robust and free of movement-induced noise.

Part
Stimulation/Recording Controller
connects to computer via USB cable
Price
M4200
RHS 128-channel stimulation/recording controller
includes USB cable and power cable
12,950.00
E6500
I/O expander
for use with controller; includes interface cable
6.35
Part
RHS Headstages
headstages include Intan chip
Price
M4016
RHS 16-channel stim/record headstage
18-pin Omnetics electrode connector
1,195.00
M4032
RHS 32-channel stim/record headstage
36-pin Omnetics electrode connector
1,620.00
Part
Cables
connect RHS headstages to controller
Price
M4563
RHS 3-ft (0.9 m) Stim SPI interface cable
(formerly part number M3203)
265.00
M4566
RHS 6-ft (1.8 m) Stim SPI interface cable
(formerly part number M3206)
350.00
M4430
Stim SPI cable adapter board
for interfacing with commutators or custom hardware
148.00
Part
Adapters
connect headstages to custom electrodes
Price
C3410
36-pin electrode adapter board
for headstages with 36-pin connector
255.00
C3418
18-pin electrode adapter board
for headstages with 18-pin connector
189.00
C3420
36-pin wire adapter
for headstages with 36-pin connector
230.00
B7600
18-pin wire adapter
for headstages with 18-pin connector
145.00
Part
Hardware Development Tools
Price
C3490
LVDS adapter board
for custom hardware development
410.00

All pricing information is subject to change without notice. Quantities may be limited. All orders are subject to current pricing at time of acceptance by Intan Technologies. Additional shipping and handling charges will apply. Intan ships using FedEx; domestic orders are shipped 2-day unless otherwise requested. Prices are given in US dollars.

Note

The RHS stim/recording system cannot use RHD recording headstages or RHD interface cables. The RHD and RHS systems are not compatible. RHS headstages do not work with the Open Ephys system.

Warranty

We guarantee our products to be free of material defects for 90 days of normal use within specification. Because our products are used in conjunction with customer hardware, we have to assess each situation on a case-by-case basis. This warranty does not apply to products that have been modified in design or function, subjected to abuse, misuse, mishandling, or unauthorized repair. Within the 90-day use period, however, if the failure is found to be strictly from our product from normal use within specification of components on-board, we will repair or replace (at our option) the product if returned to us in its original condition. Contact us for return information prior to returning any products. We do not refund shipping costs.

Order Your Advanced Data Collection System Today

Get the right tools for your research. Contact us to place an order or get a customized solution tailored to your needs.